Sterilization
Methods of sterilization can be broadly classified as:
a.
Physical methods of sterilization, and
b.
Chemical methods of sterilization.
Physical methods of sterilization include the following:
a.
Sunlight
b.
Heat
c.
Filtration
d.
Radiation
e.
Sound (sonic) waves
Direct sunlight is a natural method of sterilization of water in
tanks, rivers, and lakes. Direct sunlight has an active germicidal effect due
to its content of ultraviolet and heat rays. Bacteria present in natural water
sources are rapidly destroyed by exposure to sunlight.
Heat is the most dependable method of sterilization and is usually
the method of choice unless contraindicated. As a rule, higher temperatures
(exceeding the maximum) are microbicidal, whereas lower
temperatures (below the minimum) tend to have inhibitory or microbistatic
effects. Two types of physical heat are used in sterilization—moist and dry
heat.
Moist heat occurs in the form of hot water, boiling water, or steam
(vaporized water). In practice, the temperature of moist heat usually ranges
from 60 to 135°C. Adjustment of pressure in a closed container can regulate the
temperature of steam. Moist heat kills microorganisms by denaturation and
coagula-tion of proteins. Sterilization by moist heat can be classified as
follows:
1.
Sterilization at a temperature ,100°C
2.
Sterilization at a temperature of 100°C
3. Sterilization at a
temperature .100°C
4.
Intermittent sterilization
Pasteurization:Fresh beverages (such as
milk, fruit juices,beer, and wine) are easily contaminated during collection
and processing. Because microbes have potential for spoil-ing these foods or
causing illness, heat is frequently used to reduce the microbial load and to
destroy pathogens. Pasteurization is a technique in which heat is applied to
liq-uids to kill potential agents of infection and spoilage, while at the same
time retaining the liquid’s flavor and food value. This technique is named
after Louis Pasteur who devised this method. This method is extensively used
for steriliza-tion of milk and other fresh beverages, such as fruit juices,
beer, and wine which are easily contaminated during collec-tion and processing.
The flash method is preferable for sterilization of milk because it
is less likely to change the flavor and nutrient content, and it is more
effective against certain resistant pathogens, such as Coxiella and Mycobacterium.
Although pasteurization inactivates most
viruses and destroys the vegetative stages of 97–99% of bacteria and fungi, it
does not kill endospores or thermoduric
species (mostly nonpathogenic lactobacilli, micrococci, and yeasts). Milk is
not sterile after regular pasteurization. In fact, it can contain 20,000
microbes per milliliter or more, which explains why even an unopened carton of
milk will eventually spoil on prolonged storage. Newer techniques have now been
used to produce sterile milk that has a stor-age life of 3 months. In this
method, milk is processed with ultrahigh
temperature (UHT) of 134°C for 1–2 seconds.
2. Sterilization at a
temperature of 100°C: Sterilsation ata temperature of 100ºC includes (a) boiling and (b) steam sterilizer at 100°C.
Boiling:Simple boiling of water for
10–30 minutes killsmost of the vegetative forms of bacteria but not bacterial
spores. Exposing materials to boiling water for 30 minutes kills most
nonspore-forming pathogens including resis-tant species, such as the tubercle
bacillus and staphylo-cocci. Sterilization by boiling is facilitated by
addition of 2% sodium bicarbonate to water. Since boiling only once at 100°C
does not kill all spores, this method cannot be used for sterilization but only
for disinfection. Hence, it is not recommended for sterilizing instruments used
for surgical procedure. The greatest disadvantage of this method is that the
items sterilized by boiling can be easily recontami-nated when removed from
water after boiling.
Steam sterilizer at 100°C:Usually, Koch’s or
Arnold’ssteam sterilizer is used for heat-labile substances that tend to
degrade at higher temperatures and pressure, such as during the process of
autoclaving. These substances are exposed to steam at atmospheric pressure for
90 minutes during which most vegetative forms of the bacteria except for the
thermophiles are killed by the moist heat.
3. Sterilization at a
temperature > 100°C: This method isotherwise known
as sterilization by steam under pressure. A temperature of 100°C is the highest
that steam can reach under normal atmospheric pressure at sea level. This
pressure is measured at 15 pounds per square inch ( psi), or 1 atmosphere. In order to raise the temperature of steam
above this point, it must be pressurized in a closed chamber. This phenomenon
is explained by the physical principle that governs the behavior of gases under
pres-sure. When a gas is compressed, its temperature rises in direct relation
to the amount of pressure. So, when the pressure is increased to 5 psi above
normal atmospheric pressure, the temperature of steam rises to 109°C. When the
pressure is increased to 10 psi above normal, its tem-perature will be 115°C
and at 15 psi (a total of 2 atmo-spheres), it will be 121°C. It is not the
pressure by itself that is killing microbes, but the increased temperature it
produces. This forms the principle of sterilization by steam under pressure.
Such pressure–temperature combi-nations can be achieved only with a special
device that can subject pure steam to pressures greater than 1 atmo-sphere.
Health and commercial industries use an autoclave
for this purpose and a comparable home appliance is the pressure cooker.
Autoclave:It is a cylindrical metal
chamber with an airtightdoor at one end and racks to hold materials. The lid is
fastened by screw clamp and rendered airtight by an asbestos washer. It has a
discharge tap for air and steam at the upper side, a pressure gauge and a
safety valve that can be set to blow off at any desired pressure. Heating is
usually carried out by electricity. Steam circulates within the jacket and is
supplied under pressure to the inner chamber where materials are loaded for
sterilization (Fig. 3-1). The water in the autoclave boils when its vapor
pressure equals that of surrounding atmosphere. Following the increase of
pressure inside the closed vessel, the temperature at which the water boils
inside the autoclave also increases. The saturated steam that has a higher
penetrative power, on coming in contact with a cooler surface condenses to
water and releases its latent heat to that surface. For example, nearly 1600 mL
steam at 100°C and at atmospheric pressure condenses into 1 mL of water at
100°C and releases 518 calories of heat. The gross reduction in volume of steam
sucks in more steam to the area and this process continues till the temperature
of that surface is elevated to that of the steam. Sterilization is achieved
when the steam condenses against the objects in the chamber and gradually
raises their temperature. The condensed water facilitates moist conditions that
ensures killing of microbes.
Sterilization condition: Experience has shown that
the mostefficient pressure–temperature combination for achiev-ing sterilization
by autoclave is 15 psi, which yields 121°C. It is possible to use higher
pressure to reach higher tem-peratures (for instance, increasing the pressure
to 30 psi raises the temperature by 11°C), but doing so will not significantly
reduce the exposure time and can harm the items being sterilized. It is
important to avoid over packing or haphazardly loading the chamber, because it
prevents
However, the autoclave is ineffective for sterilizing substances
that repel moisture (oils, waxes, or powders). Types and uses of various moist
heat sterilization methods are summarized in Table 3-1.
Sterilization controls: Various sterilization
controls are usedto determine the efficacy of sterilization by moist heat.
These include (a) thermocouples, (b) chemical indicators, and (c) bacteriological spores as mentioned
below:
a.
Thermocouples are used to record temperatures directly in
autoclaves by a potentiometer.
b.
Brown’s tube is the most commonly used chemical indicator of moist
heat sterilization in the autoclave. It contains red solution that turns green
when exposed to temperature of 121°C for 15 minutes in an autoclave.
c.
Bacillus stearothermophilusspores are used as
theindicators of moist heat sterilization in the autoclave. This is a
thermophilic bacterium with an optimum temperature of 55–60°C, and its spores
require an exposure of 12 minutes at 121°C to be destroyed. The efficacy of the
autoclave is carried out by placing paper strips impregnated with 106spores
in envelopes and keeping those envelopes in different parts of the load inside
the autoclave. These strips after sterilization are inoculated into a suitable
recovery medium and
d. Intermittent
sterilization: Certain heat-labile substances(e.g., serum, sugar, egg, etc.) that
cannot withstand the high temperature of the autoclave can be sterilized by a
process of intermittent sterilization, known as tyndallization.
Tyndallizationis carried out over a period
of 3 days andrequires a chamber to hold the materials and a reservoir for
boiling water. Items to be sterilized are kept in the cham-ber and are exposed
to free-flowing steam at 100°C for 20 minutes, for each of the three
consecutive days. On the first day, the temperature is adequate to kill all the
vegetative forms of the bacteria, yeasts, and molds but not sufficient to kill
spores. The surviving spores are allowed to germi-nate to vegetative forms on the
second day and are killed on re-exposure to steam. The third day re-ensures
killing of all the spores by their germination to vegetative forms.
Intermittent sterilization is used most often
to sterilize heat-sensitive culture media, such as those containing sera (e.g.,
Loeffler’s serum slope), egg (e.g., Lowenstein–Jensen’s medium), or
carbohydrates (e.g., serum sugars) and some canned foods.
Sterilization by dry heat makes use of air with a low mois-ture
content that has been heated by a flame or electric heat-ing coil. In practice,
the temperature of dry heat ranges from 160°C to several thousand degrees
Celsius. The dry heat kills microorganisms by protein denaturation, oxidative
damage, and the toxic effect of increased level of electrolytes. Dry heat is
not as versatile or as widely used as moist heat, but it has several important
sterilization applications. The temperature and time employed in dry heat vary
according to the particular method, but in general they are greater than with
moist heat. Sterilization by dry heat includes sterilization by (a) flaming, (b) incineration , and (c)
hot air oven:
Flaming: Sterilization of inoculating
loop or wire, the tipof forceps, searing spatulas, etc., is carried out by
holding them in the flame of the Bunsen burner till they become red hot. Glass
slides, scalpels, and mouths of culture tubes are sterilized by passing them
through the Bunsen flame without allowing them to become red hot.
Incineration: Incineration is an excellent
method forsafely destroying infective materials by burning them to ashes. It
has many uses:
Incinerators are used to carry out this process
and are regularly employed in hospitals and research labs to destroy hospital
and laboratory wastes.
The method is used for complete destruction and
dis-posal of infectious material, such as syringes, needles, culture material,
dressings, bandages, bedding, animal carcasses, and pathology samples.
This method is fast and effective for most
hospital wastes, but not for metals and heat-resistant glass materials.
Hot-air oven: The hot-air oven provides another means ofdry
heat sterilization and is the most widely used method. The hot-air oven is
electrically heated and is fitted with a fan to ensure adequate and even distribution of hot air in
the chamber. It is also fitted with a thermostat that ensures circulation of
hot air of desired temperature in the chamber. Heated, circulated air transfers
its heat to the materials inside the chamber. While sterilizing by hot-air
oven, it should be ensured that the oven is not overloaded. The materials
should be dry and arranged in a manner which allows free circulation of air
inside the chamber. It is essential to fit the test tubes, flasks, etc., with
cotton plugs and to wrap Petri dishes and pipettes in a paper. Steriliza-tion
by hot-air oven requires exposure to 160–180°C for 2 hours and 30 minutes,
which ensures thorough heating of the objects and destruction of spores (Fig.
3-2).
Thermocouples, chemical indicators, and bacteriological spores of Bacillus subtilis are used as
sterilization controls to determine the efficacy of sterilization by hot-air
oven.
◗
Filtration
Filtration is an excellent way to reduce the microbial popula-tion
in solutions of heat-labile material by use of a variety of filters. Filters
are used to sterilize these heat-labile solutions.
Filters simply remove contaminating microorganisms from solutions
rather than directly destroying them. The filters are of two types: (a) depth filters and (b) membrane filters.
1. Depth filters: Depth filters consist of fibrous or
granularmaterials that have been bonded into a thick layer filled with twisting
channels of small diameter. The solution contain-ingmicroorganisms is sucked in
through this layer under vacuum and microbial cells are removed by physical
screen-ing or entrapment and also by adsorption to the surface of the filter
material. Depth filters are of the following types:
Candle
filters: These
are made up of (a) diatomaceousearth
(e.g., Berkefeld filters) or (b)
unglazed porcelain (e.g., Chamberlain filters). They are available in
differ-ent grades of porosity and are used widely for purifica-tion of water
for drinking and industrial uses.
Asbestos
filters: These
are made up of asbestos such as mag-nesium silicate. Seitz and Sterimat filters
are the examples of such filters. These are disposable and single-use discs
available in different grades. They have high adsorbing capacity and tend to
alkalinize the filtered fluid. Their use is limited by the carcinogenic
potential of asbestos.
Sintered
glass filters: These
are made up of finely pow-dered glass particles, which are fused together. They have low
absorbing property and are available in different pore sizes. These filters,
although can be cleaned easily, are brittle and expensive.
2. Membrane filters: Membrane filters are made up
of (a)cellulose acetate, (b) cellulose nitrate, (c) polycarbonate, (d) polyvinylidene fluoride, or (e)
other synthetic materials. These filters are now widely used and have replaced
depth filters for last many years. These filters are circular porous membranes
and are usually 0.1 mm thick. Although a wide variety of pore sizes (0.015–12 mm) are available, mem-branes
with pores about 0.2 mm are used, because the pore size is smaller than the size of
bacteria. These filters are used to remove most vegetative cells, but not
viruses, from solutions to be filtered. In the process of filtration, the
membranes are held in special holders and often preceded by depth filters made
of glass fibers to remove larger parti-cles that might clog the membrane
filter. The solution is then pushed or forced through the filter with a vacuum
or with pressure from a syringe, peristaltic pump, or nitrogen gas bottle, and
collected in previously sterilized containers.
Air also can be sterilized by filtration. Two common exam-ples are
surgical masks and cotton plugs on culture vessels that let air in but keep
microorganisms out. Laminar flow biological safety cabinets are most widely
used air filtration systems in hospitals and industries. In this method, air is
passed through high-efficiency particulate air (HEPA) filters that remove
nearly 99.97% of 0.3 mm particles from the filtered air.
◗
Radiations
The ionizing and nonionizing radiations are the two types of radiation
used for sterilization (Table 3-2).
1. Ionizing radiations: Ionizing radiation is an excellentsterilizing
agent with very high penetrating power. These radiations penetrate deep into
objects and destroy bacterial endospores and vegetative cells, both prokaryotic
and eukaryotic. These are, however, not that effective against viruses.
Ionizing radiations include (a)
X-rays, (b) gamma rays, and (c) cosmic rays. Gamma radiation from a
cobalt-60 source is used for sterilization of antibiotics, hormones, sutures,
catheters, animal feeds, metal foils, and plastic disposables, such as
syringes. This has also been used to sterilize and “pasteurize” meat and other
food items.
Irradiation usually
kills Escherichia coli O157:H7, Staphylococcus
aureus, Campylobacter jejuni, and other patho-gens. Since there is no detectable increase of temperature in this
method, this method is commonly referred to as “cold sterilization.” Both
the Food and Drug Administration and the World Health Organization have approved
food irradiation and declared it safe.
2. Nonionizing radiations: Nonionizing radiations includeinfrared and
ultraviolet radiations.
o Infrared radiations are used for rapid and mass steriliza-tion of
disposable syringes and catheters.
o Ultraviolet (UV) radiation with wavelength of 240–280 nmis quite lethal
and has a marked bactericidal activity. It acts by denaturation of bacterial
protein and also inter-feres with replication of bacterial DNA.
UV radiation is used primarily for disinfection of closed areas in
microbiology laboratory, inoculation hoods, laminar flow, and operating
theaters. It kills most vegetative bacteria but not spores, which are highly
resistant to these radiations. However, it does not penetrate glass, dirt
films, water, and other sub-stances very effectively.
Since UV radiations on
prolonged exposure tend to burn the skin and cause damage to the eyes, UV lamps
should be switched off while people are working in such areas.
◗
Sound (sonic) waves
High-frequency sound (sonic)
waves beyond the sensitivity of the human ear are known to disrupt cells.
Sonication transmits vibra-tions through a water-filled chamber (sonicator) to
induce pres-sure changes and create intense points of turbulence that can
stress and burst cells in the vicinity. Sonication also forcefully dislodges
foreign matter from objects. Heat generated by the sonic waves (up to 80°C)
also appears to contribute to the antimicrobial action.
Gram-negative rods are most
sensitive to ultrasonic vibra-tions, while Gram-positive cocci, fungal spores,
and bacterial spores are resistant to them. Ultrasonic devices are used in
dental and some medical offices to clear debris and saliva from instruments
before sterilization and to clean dental restorations. However, most sonic
machines are not reliable for regular use in disinfection or sterilization.
Biological controls used
for testing the efficacy of steriliza-tion techniques are summarized in Table
3-3.
Several chemical agents are used as antiseptics as well as
dis-infectants. All these chemical agents (e.g., alcohols, aldehydes, etc.) are
described later in detail under disinfection.
The effects of cold and desiccation: The main benefit ofcold
treatment is to slow the growth of cultures and microbes in food during
processing and storage. It is essential to know that
Although it is
true that cold temperatures kill some microbes, gradual cool-ing, long-term
refrigeration, or deep-freezing does not adversely affect most of the
microorganisms. In fact, freezing tempera-tures, ranging from 270 to 2135°C, provide an environment
that can preserve cultures of bacteria, viruses, and fungi for lon-ger periods.
Some psychrophiles grow very slowly even at freez-ing temperatures and can
continue to secrete toxic products.
S. aureus, Clostridium species
(spore formers), Streptococcus species,and
several types of yeasts, molds, and viruses are the pathogens that can survive
for several months in the refrigerated food items.
As a general rule,
chilling, freezing, and desiccation are not considered as methods of
disinfection or sterilization because their antimicrobial effects are erratic
and uncertain, and one cannot be sure that pathogens subjected to these
procedures have been killed.