FORM WORK
General:
The form work shall consist of shores, bracings, sides of
beams and columns, bottom of slabs etc, including ties, anchors, hangers,
inserts etc. complete which shall be properly designed and planned for the
work. The false work shall be so constructed that up and down vertical
adjustment can be made smoothly. Wedges may be used at the top or bottom of
timber shores, but not at both ends, to facilitate vertical adjustment and
dismantling of form work.
Design of
Form Work
The design and engineering of form work as well as
its construction shall be the responsibility of Contractor. The drawings and
calculations for the design of the form work shall be submitted well in advance
to the Engineer-in-charge for approval before proceeding with work, at no extra
cost to the Department. Engineer-in-charge's approval shall not however,
relieve Contractor of the full responsibility for the design and construction
for the form work. The design shall take into account all the loads vertical as
well as lateral that the
forms
will be carrying including live and vibration loadings.
Tolerances:
Tolerances are specified permissible variation
from lines, grade or dimensions given in drawings. No tolerances specified for
horizontal or vertical buildings lines or footings. Unless otherwise specified,
the following tolerances will be permitted.
Tolerances
for R.C. Buildings: I) Variation from the plumb:
a) In the
line ad surfaces of columns, piers, walls and in buttresses: 5 mm per 2.5m, but
not more than 25 mm.
b) For
exposed corner columns ad other conspicuous lines
In any
bay or 5 m, maximum : (+) 5 mm In 10 m or more: (+) 10mm
ii) Variation
from the level or from the grades indicated on the drawings.
a) In slab
soffits, ceilings, beam soffits and in arises.
b) In 2.5m
(+) 5mm In any bay or 5m maximum (+) 8 mm In 10 or more (+) 15mm
c) For
exposed lintels, sills, parapets, horizontal grooves and conspicuous lines
iii) Variation
of the linear building lines from established position in plan and related
position of columns, walls and partitions. In any bay or 5m maximum (+) 10 mm
In 10 or more (+)
20mm
iv) Variation
in the sizes ad locations of sleeves, openings in walls and floors except in
the case of and for anchor bolts : (+) 5mm
Variation
in cross sectional dimensions of columns and beams and in the thickness of
slabs and walls: (+) 10 mm/(-)5mm
vi)Footing :
a) Variation
in dimensions in plan (+) 50mm/(-) 5mm.V- Page 55 of 197
b) Misplacement
or eccentricity: 2% of footing within the direction of misplacement but not
more than 50mm.
c) Reduction
in thickness (-) 5% of specified thickness subject to maximum of 50mm. vii)
Variation in steps:
a) In a flight of stairs Rise (+) 3.0 mm
Tread (+)
5.0 mm
b)
Consecutive steps Rise (+) 1.5 mm Tread (+) 3.0 mm