Signalling Systems
The entire signalling system can be classified into two main
categories.
(a) Mechanical
signalling system
(b) Electrical
signalling system
In addition to these two main
categories of signalling systems, a solid-state signalling system is also in
use. Each system of signalling comprises four main components.
(a) Operated
units such as signals and points
(b) A
transmission system such as single- or double-wire transmission or electrical
transmission
(c) Operating
units such as levers and press buttons
(d) Monitoring
units such as detectors, treadle bars, and track circuiting
The comparison between mechanical
and electrical signalling based on these four broad components is given in
Table 31.8.
Table 31.8 Comparison of signalling
systems
A.Mechanical Signalling System
The mechanical signalling system
mostly involves signals and points as explained in this section.
1 Signals
The signals used in a mechanical
signalling system are semaphore signals. These signals are operated by means of
either a lower quadrant or an upper quadrant signalling system.
Lower quadrant signalling system
This system of signalling was
designed so that the semaphore arm of the signal could be kept either
horizontal or lowered. The lower left-hand quadrant of a circle is used for
displaying a semaphore indication to the driver of a train. This concept was
possibly developed based on the left-hand driving rules applicable on roads in
the UK and in India.
Upper quadrant signalling system
In lower quadrant signalling, the
semaphore arm of the signal can only take two positions, namely, horizontal or
lower; it is not possible to include a third position for the semaphore arm,
such as vertically downward position, due to design as well as visibility
problems, since as the semaphore arm would, in that case, be super imposed on
the signal post. Due to this limitation, the upper quadrant system was developed,
which can display more than two aspects. In this system, it is possible to
incorporate three positions of the semaphore arm, namely, (a) horizontal,
(b)inclined at an angle of about
45 o above the horizontal level, and (c) vertical, i.e., inclined at an angle of
90 o above the horizontal level. See Fig. 31.14. The positions of the arm, the
corresponding indications, and their meanings are listed in Table 31.9.
2 Points
Points are set mechanically and
are kept in locks and stretcher bars. The mechanical arrangement for operating
them includes a solid rod with a diameter of 33 mm running from the lever
provided in the cabin and connected to the point through cranks. Owing to
transmission losses, the operating points with rods is restricted to a
specified distance from the cabin.
Table 31.9 Details of upper
quadrant signals
The following devices are used to
ensure that the points are held rigidly in the last operated position under a
moving train and to ensure absolute integrity of the same.
(a) Point
locks to hold the point in the required position and to rigidly hold the point
in the position of the last operation.
(b) Detectors
to detect lock and switches.
(c) Lock bars
to prevent the movement of points when a train is passing over
them.
These
devices are further discussed in the subsequent paragraphs.
Point locks
A point lock is provided to
ensure that each point is set correctly. It is provided between two tongue
rails and near the toe of the switch assembly. The point lock consists of a
plunger, which moves in a plunger casing. The plunger is worked by means of a
plunger rod, which is connected to the signal cabin through a lock bar.
Additionally, there are a set of stretcher blades and each blade is connected
to one of the tongue rails. Each blade has two notches and they move inside the
plunger casing along with the tongue rails. When the points are set correctly
for a particular route, the notch in the stretcher blade rests in its proper
position and the plunger rod enters the notch, locking the switch in the last
operated position.
Detectors
Detectors are normally provided for all the points for the
following reasons.
(a) To detect
any defect or failure in the connection between the points and the lever as
well as any obstruction between the stock and the tongue rail.
(b) To ensure
that the correct signal, which corresponds to the point set, is lowered.
(c) A
detector can be mechanical or electrical. In the case of a mechanical
detector, the point is held in the position of the last
operation, which is achieved de facto by virtue of its design.
A detector normally consists of a
detector box, which is provided with one slide for points and another set of
slides for signals. The signal slides are perpendicular to the point slides.
The slides are held suitably and no vertical movement of its same is possible.
The signal slide has only one notch whereas the point slide has a number of
notches depending upon the number of signals relevant to the points. The
detector works on the principle that a particular signal can be lowered when
the notch in that particular signal slide coincides with the notch in the point
slide. For example, if the points are correctly set for the main line, the
point slide moves and its notch comes to rest opposite the notch of the main
line signal slide. The main line signal slide can then be pulled and the main
line signal lowered. It may be noted here that the point slide will move and
its notch will rest in its correct position only if the points are properly set
and there is no obstruction in between.
The linear type (or slide type)
of mechanical detector is used for single-wire signalling (Fig. 31.15), whereas
the rotary type of detector (Fig. 31.16) is used for the double-wire
signalling. A double-wheel detector is a rotary-type detector that rotates in a
vertical plane. It detects the correct setting of points and, in addition,
locks the points in the last operated position in the case of wire breakage.
Lock bar
A lock bar is provided to make it
impossible to change the point when a train is passing over it. The lock bar is
made of an angled section and its length is greater than that of the longest
wheel base of a vehicle. Short revolving clips are provided to hold the lock bar
in place on the inside face of one of the rails. The length of a lock bar is
normally 12.8 m for BG and 12.2 m for MG sections.
The system is so designed that
when the lever in the cabin is pulled to operate the locking device, the lock
bar rises slightly above the rail level and then comes down. In the occurrence
that a vehicle is positioned on the same location, the lock bar cannot rise
above the rail level due to the flanges of the wheel and as such the point
cannot be operated.
3 Different Transmission Systems
A signal is operated by pulling
the associated lever and this action is transmitted through a single-wire or
double-wire system. Initially, the single-wire system was the most popular way
of operating signals and, in fact, some stations on Indian railways still use
this system.
In the single-wire system, only
one wire is stretched between the operating lever and the signal, whereas in
the double-wire system a loop of two wires that run parallel to each other is
wrapped over a drum lever and this system works on the principle of the pull
and push arrangement.
Single-wire transmission
In the case of single-wire
signalling, transmission is done with the help of the following equipment.
Lever frame A lever
frame carries out the dual function of operating the single-wire system and
actuating the interlocking in order to ensure safety. There are two types of
lever frames, namely, a direct locking lever frame and a catch handle type
lever frame, which are used for this purpose on the Indian Railways. The levers
are pulled in order to operate the signals.
Signal transmission wire The
entire transmission is done through an 8 or 10 SWG (standard wire
gauge) galvanized steel wire. In places where the transmitting wire has to
manoeuvre a turn, a multistandard galvanized steel wire is used, which is
hauled over a horizontal or vertical wheel by pulling the lever. The arm of the
signal remains as such while the lever is being pulled. When the lever returns
to its normal position, the counterweight provided with the signal arm restores
the wire back to its original position.
Cabin wire adjuster In order
to accommodate the increase or decrease in the length of the
cabin wire due to its expansion as a result of temperature variation, cabin
wire adjusters are provided. If this is not done, it may result in inadequate
lowering or drooping of the signal, thus giving rise to unsafe conditions.
Signal parts and fitting Signal
parts and fittings are provided as per the details given in Fig.
31.2. The signal arm is brought to the 'off' position by a down rod. In the
case of a breakdown of the signal transmission system, the signal arm is
brought back to the horizontal position by means of a counterweight.
Limitations of single-wire
signalling The single-wire signalling system does not give
satisfactory performance in the operation of signals located at long distances.
The signals do not operate correctly as they droop and do not get properly
lowered, thereby endangering the trains. This defect develops due to the
following reasons.
(a) Sagging
of the wire due to its own weight.
(b) Expansion
or contraction of the wire due to temperature variations.
(c) The
elastic stretching of wires due to tension arising as a result of operating the
lever.
(d) Entangling
of the wire due to its slipping into the pulley stake and the horizontal and
vertical wheels.
(e) Frequently
breakage of the wire.
It has been noticed that the
slightest slackness in attending to any one of these problems can cause the
lowering of the signal, known as 'drooping', even when the lever is not pulled.
On account of these defects, situations may arise in which a signal may not be
lowered at all or a signal may not return to the 'on' position even after the
lever has been restored to its normal position, if the wire gets entangled. As
a result of these limitations, the single-wire signalling system can be used
for operating signals from a range of only about 950 m.
Rod transmission In the
single-wire transmission system, the signal is lowered or set in the
'off' position by pulling the lever. The signal returns to the 'on' position
due to the effect of gravity as soon as the lever is restored to its normal
position and the tension in the wire is released.
Where the operation of points is
concerned, the points have to be set in either the normal or the reverse
position; one of these positions can be attained through pulling and the other
by pushing. Solid rods of 30 mm (1¼" ) diameter are used to connect
the levers to the points. The rods or pipes move on standard roller guides
fixed at about 2-m (6-ft) intervals. A suitable crank is also used at every
change of direction. The rods are subjected to expansion and contraction due to
temperature variations.
Rod temperature compensator A rod
compensator, also known as a temperature compensator, is provided
to neutralize the effect of thermal. It consists of a pair of cranks, one acute
and one obtuse, connected by a link and is so designed that it absorbs the
expansion or contraction due to temperature variations. The compensator is
normally placed at the centre of the rod up to a length of 36.5 m. If more than
one compensator is required, these are placed at quarter points.
As can be seen in Fig. 31.17, the
points, A or B may move left or right, but the total distance between them
remains the same.
Double-wire transmission system
In this system, power is
transmitted with the help of two wires from the lever to operated units such as
signals, points, locks, detectors, etc. Each wire consists of 8 to 10 SWG solid
galvanized steel wires attached to pulley stakes, which are driven firmly into
the ground. The two wires are connected between the lever and the signal to
form a continuous loop. When the lever is operated, it leads to the wire getting
pulled and when the lever is brought back to its normal position, it results in
a push to the wire. This pull and push mechanism (Fig. 31.18) causes the drum
to rotate in one direction when the lever is pulled and in the other direction
when it is restored to its normal position. The rotary motion of the drum is
then converted into linear movement by the use of cams and cranks and this
finally actuates the signal, as illustrated in Fig. 31.19, which shows the
complete double-wire transmission system.
Advantages of double-wire
transmission The main advantages of double-wire transmission
over single-wire transmission are enumerated here.
(a) Operating
a double-wire transmission system is easier.
(b) A
double-wire transmission system permits multi-aspect signalling.
(c) The range
of operations of the double-wire transmission system is greater.
(d) There is
no drooping of signals in double-wire transmission. This results in better
safety.
(e) The
operating cost of a double-wire transmission system is less.
Table 31.10 compares a
signal-wire and a double-wire signalling system. The special features of a
double-wire signalling system are as follows.
Table 31.10 Comparison
of transmission systems
(a) Double
wire compensators are provided to perform the following functions.
(i) To
maintain constant tension in the transmission system by adjusting the changes
in length caused by temperature variations.
(ii)
To provide protection against wire breakage.
Whenever a wire breaks, the following compensator ensures that the signal is
brought to the 'safe' position.
(b) Jockey
weights are added to the main compensator weight to cater to a greater
operating force.
(c) Coupling
devices are provided to detect the couplings of two levers in a common transmission.
(d) Double-wire
detectors are provided to detect the correct setting of the points and locks.
4 Operating Mechanism
In mechanical signalling, the
signals and points are operated mechanically. The operation of these units,
therefore, requires sufficient amount of power. To facilitate the quick and
smooth operation of these equipment, levers are used in single-wire as well as
in double-wire mechanical transmission. These levers may be installed
individually near an operated unit such as a point or a signal or may be
grouped together in a lever frame depending upon the type and standard of
signalling. Lever frames may be of the following types.
Single-wire lever frame
In this type of lever frame, the
lever is a bar fulcrumed on a shaft. The longer end of the bar rests towards
the lever while the shorter end rests towards the signal or the point in order
to gain mechanical advantage. Pulling the lever results in a movement of 200 mm
in the case of points and 300 mm in the case of signal operation. All the
levers that are required to operate different units such as points and signals
are grouped together on a common fulcrum shaft in a compact lever frame, which
is kept below the level of the operation platform. Only a convenient length of
the lever is allowed to protrude beyond the platform to facilitate easy
operation. A latch arrangement is also provided with the lever arm to maintain
the lever in the position in which it was last operated.
Double-wire lever frames
Unlike single-wire systems, a
double-wire transmission system is in the form of a loop, one end of which is
wrapped across a drum that is provided with an arm. When this arm is rotated
about the centre of the drum, it imparts a stroke of 550 mm or 600 mm depending
upon the type of lever used. There are six types of double-wire levers used on
Indian Railways that impart strokes of 500 mm to 600 mm.
When referring to points,
normally a 500-mm stroke drum is capable of operating all the equipment
satisfactorily up to a distance of 500 m. In the case of any difficulty, 600-mm
stroke levers may be used.
The
interlocking of these operating mechanisms is discussed in Section 31.9.
5 Monitoring Units
Monitoring units are provided to
ensure that points are set properly and locked for the safe passage of trains.
These units are also sometimes used to monitor the passage of trains. Detectors
and treadles are used as monitoring devices on Indian Railway. Detectors have
been discussed in Section 31.6.2.
Treadle for monitoring passage of train
It is not always possible for a
train to pass immediately after the route has been set for its reception or
departure and the signals have been placed in the 'off' position. There is
generally a time gap between these two events. During this intervening period,
the operator has to conduct many other operations in the yard such as the
shunting of some other train, monitoring the movement of other trains, and
booking tickets, and in the process, the operator is likely to forget about the
passage of the train on the route set by him. In order to eliminate human
error, some devices are provided to monitor the presence or passage of a train
over a defined portion of the track. Most of these devices are either
electrical or electronic. However, the basic electro-mechanical device used for
monitoring the passage of a train is a treadle. A treadle unit is
fastened with the rails. The passage of the train deflects the point of
contact, which is transmitted to the cabin thereby proving and confirming the
passage of the train.
B.
Electrical Signalling System
The electrical signalling system
is progressively replacing the mechanical signalling system on Indian Railways,
especially with the coming up of railway electrification projects. The main
reasons behind this are as follows.
(a) There are
a number of movable parts in the mechanical signalling system such as rods,
wires, and cranks, which cause heavy wear and tear, frictional losses, and many
of these parts can be sabotaged by unauthorized persons.
(b) The arms
of the semaphore signals used in mechanical signalling afford poor visibility
during the day. The night indications of these signals are also not
satisfactory.
(c) The
operational time of the mechanical signalling system is much greater than that
of the electrical signalling system.
In the electrical signalling
system, electrical energy is used for displaying signals. The transmission of
power is done electrically and the units are operated by electrical push
buttons while system is monitored by electrical systems.
1 Operated Units
The operated units consist of
signals and points. The electrical signalling system is either coloured light
signals or signals with semaphore arms operated by electric motors.
A point is operated by converting
the rotary movement of the electrical point machines fastened on the sleepers
near the point into a linear push or pull force. There are low-voltage point
machines operated with a 24-V dc supply and high-voltage point machines
operated using a 110-V dc supply. The operation of a point machine involves
first unlocking the lock, bringing the point from normal to reverse or reverse
to normal as the case may be, and then locking the point once again. The
operating time of these point machines varies between 3 and 5 sec.
2 Transmission Medium
The medium of transmission for
operating electrical equipment is either an overhead alignment or an
underground cable. The overhead alignment is used when the number of conductors
is limited. In areas provided with 25-kV ac traction, it is not possible to use
overhead alignments due to the induced electromotive force (EMF) generated as a
result of electrostatic and electromagnetic induction. In big yards, cables are
used as a medium of transmission for the operation of point machines. The
cables are either hung on hooks and run by the side of the track or laid
underground. In areas provided with ac traction, under ground screened cables
are used.
3 Operating System
Normally push buttons and rotary
switches are used for operating signalling equipment that work on electricity.
The complete yard layout is represented on the face of a console. Signals,
tracks, points, and the gates of level crossings are depicted in their
geographical positions on this console and the positions of these switches are
then marked at the foot of signals and on various tracks.
Complete interlocking is achieved
through electromagnetic switches known as relays. The two methods of
interlocking available are panel interlocking or route relay
interlocking. The details of these two systems of interlocking are given in
Section 31.9.
4 Monitoring System
It mainly consists of point
detectors, track circuits, and axle counters, all of which are discussed here
in detail.
Electrical point detector
The electrical point detector
detects and ensures that points are properly set. It also works on a 'slide
system' as used in the mechanical system. These slides are so adjusted that a
gap of 3 mm is left between the switch rail and the stock rail so that the two
do not come is contact and, therefore, it is not possible to turn the signal
off at any time.
Track circuit
The track circuit is an electric
circuit formed along with the running rails and connected to the signal and
cabin. Its function is to indicate the presence of a train (or vehicle) on the
track. In order to set up a track circuit, the ends of the rails forming the
circuit are isolated by insulating the rail joints. The rails are laid on
wooden sleepers so that they are electrically insulated from each other. The
ends of the rail on one side of the track are connected to a battery through
resistances, etc., while on the other side of the track, the ends of the rails
are connected to a relay. When the track is free, energy from the battery
reaches the relay and energizes it. As soon as the track is occupied, the two
rails are short-circuited because of the wheels and axle of the train and the
relay does not get any feed from the battery. It, therefore, gets de-energized,
thereby breaking the circuit connected with the signals, thus ensuring that the
necessary signals are set to indicate danger. The various types of track
circuits used on the Railways are as follows.
(a) Direct
current track circuit
(b) Alternating
current track circuit
(c) Electronic
track circuit
Axle counters
As already mentioned, two
consecutive rails need to be insulated from each other for setting up a track
circuit. The most essential requirement for track circuiting is the use of
wooden sleepers. Due to the shortage of wooden sleepers on Indian Railways, an
attempt is being made to progressively use a device known as an axle counter,
which can be used as a substitute for track circuiting to detect the presence
or absence of a vehicle on a track. A pair of rail inductors are installed
at either end of the track for counting the axles. As soon as a train enters
the track section from one end, the number of axles entering the section are
counted automatically. Similarly, when the train leaves the track section at
the other end, the axles are counted once again at the other end. If the same
number of axles are counted at both the ends, it indicates that the section is
free or unoccupied. If the number of axles counted at the exit end are less
than the axles counted at the entrance to the section, it means that the
section is still occupied.