Inductive
Transducers
An LVDT,
or Linear Variable Differential Transformer, is a transducer that converts a
linear displacement or position from a mechanical reference (or zero) into a
proportional electrical signal containing phase (for direction) and amplitude
information (for distance). The LVDT operation does not require electrical
contact between the moving part (probe or core rod assembly) and the transformer,
but rather relies on electromagnetic coupling; this and the fact that they
operate without any built-in electronic circuitry are the primary reasons why
LVDTs have been widely used in applications where long life and high
reliability under severe environments are a required, such Military/Aerospace
applications.
The LVDT
consists of a primary coil (of magnet wire) wound over the whole length of a
non-ferromagnetic bore liner (or spool tube) or a cylindrical coil form. Two
secondary coils are wound on top of the primary coil for “long stroke” LVDTs
(i.e. for actuator main RAM) or each side of the primary coil for “Short
stroke” LVDTs (i.e. for electro-hydraulic servo-valve or EHSV). The two
secondary windings are typically connected in “opposite series” (or wound in
opposite rotational directions). A ferromagnetic core, which length is a
fraction of the bore liner length, magnetically couples the primary to the
secondary winding turns that are located above the length of the core.
When the
primary coil is excited with a sine wave voltage (Vin), it generate a variable
magnetic field which, concentrated by the core, induces the secondary voltages
(also sine waves). While the secondary windings are designed so that the
differential output voltage (Va-Vb) is proportional to the core position from
null, the phase angle (close to 0 degree or close to 180 degrees depending of
direction) determines the direction away from the mechanical zero. The zero is
defined as the core position where the phase angle of the (Va-Vb) differential
output is 90 degrees.
The
differential output between the two secondary outputs (Va-Vb) when the core is
at the mechanical zero (or “Null Position”) is called the Null Voltage; as the
phase angle at null position is 90 degrees, the Null Voltage is a “quadrature”
voltage. This residual voltage is due to the complex nature of the LVDT
electrical model, which includes the parasitic capacitances of the windings.